Engineering ToolBox > Air - Temperature, Pressure and Density

Air density for pressures and temperatures ranging from 0 psi to 1000 psi and 30 to 600 deg F

Weight density of air (in pounds per cubic foot) for different gauge pressure (psi) can be found in the table below:

Density of air 1) (lb/ft3)
Air temperature (oF) Gauge Pressure (psi)
0 5 10 20 30 40 50 60 70 80 90 100
30 0.081 0.109 0.136 0.192 0.247 0.302 0.357 0.412 0.467 0.522 0.578 0.633
40 0.080 0.107 0.134 0.188 0.242 0.295 0.350 0.404 0.458 0.512 0.566 0.620
50 0.078 0.105 0.131 0.185 0.238 0.291 0.344 0.397 0.451 0.504 0.557 0.610
60 0.076 0.102 0.128 0.180 0.232 0.284 0.336 0.388 0.440 0.492 0.544 0.596
70 0.075 0.101 0.126 0.177 0.228 0.279 0.330 0.381 0.432 0.483 0.534 0.585
80 0.074 0.099 0.124 0.174 0.224 0.274 0.324 0.374 0.424 0.474 0.524 0.574
90 0.072 0.097 0.121 0.171 0.220 0.269 0.318 0.367 0.416 0.465 0.515 0.564
100 0.071 0.095 0.119 0.168 0.216 0.264 0.312 0.361 0.409 0.457 0.505 0.554
120 0.069 0.092 0.115 0.162 0.208 0.255 0.302 0.348 0.395 0.441 0.488 0.535
140 0.066 0.089 0.111 0.156 0.201 0.246 0.291 0.337 0.382 0.427 0.472 0.517
150 0.065 0.087 0.109 0.154 0.198 0.242 0.287 0.331 0.375 0.420 0.464 0.508
200 0.060 0.081 0.101 0.142 0.183 0.244 0.265 0.306 0.347 0.388 0.429 0.470
250 0.056 0.075 0.094 0.132 0.170 0.208 0.246 0.284 0.322 0.361 0.399 0.437
300 0.052 0.070 0.088 0.123 0.159 0.195 0.230 0.266 0.301 0.337 0.372 0.408
400 0.046 0.062 0.078 0.109 0.141 0.172 0.203 0.235 0.266 0.298 0.329 0.360
500 0.041 0.056 0.070 0.098 0.126 0.154 0.182 0.210 0.238 0.267 0.295 0.323
600 0.038 0.050 0.063 0.089 0.114 0.140 0.165 0.190 0.216 0.241 0.267 0.292
Density of air 1) (lb/ft3)
Air temperature (oF) Gauge Pressure (psi)
120 140 150 200 250 300 400 500 700 800 900 1000
30 0.743 0.853 0.909 1.185 1.460 1.736 2.29 1.84 3.94 4.49 5.05 5.60
40 0.728 0.836 0.890 1.161 1.431 1.702 2.24 2.78 3.86 4.40 4.95 5.49
50 0.717 0.823 0.876 1.142 1.408 1.674 2.21 2.74 3.80 4.33 4.87 5.40
60 0.700 0.804 0.856 1.116 1.376 1.636 2.16 2.68 3.72 4.24 4.76 5.28
70 0.687 0.789 0.840 1.095 1.350 1.605 2.12 2.63 3.65 4.16 4.67 5.18
80 0.674 0.774 0.824 1.075 1.325 1.575 2.08 2.58 3.58 4.08 4.58 5.08
90 0.662 0.760 0.809 1.055 1.301 1.547 2.04 2.53 3.51 4.00 4.50 4.99
100 0.650 0.747 0.795 1.036 1.278 1.519 2.00 2.48 3.45 3.93 4.42 4.90
120 0.628 0.721 0.768 1.001 1.234 1.467 1.933 2.40 3.33 3.80 4.26 4.73
140 0.607 0.697 0.742 0.967 1.193 1.418 1.868 2.32 3.22 3.67 4.12 4.57
150 0.597 0.686 0.730 0.951 1.173 1.395 1.838 2.28 3.17 3.61 4.05 4.50
200 0.552 0.634 0.675 0.879 1.084 1.289 1.698 2.11 2.93 3.34 3.75 4.16
250 0.513 0.589 0.627 0.817 1.088 1.198 1.579 1.959 2.72 3.10 3.48 3.86
300 0.479 0.550 0.586 0.764 0.941 1.119 1.475 1.830 2.54 2.90 3.25 3.61
400 0.423 0.486 0.518 0.675 0.832 0.989 1.303 1.618 2.25 2.56 2.87 3.19
500 0.379 0.436 0.464 0.604 0.745 0.886 1.167 1.449 2.01 2.29 2.58 2.86
600 0.343 0.394 0.420 0.547 0.675 0.802 1.057 1.312 1.822 2.08 2.33 2.59

1) Density is based on atmospheric pressure 14.696 psia and molecular weight of air 28.97

Density of air can also be expressed as

ρ = 1.325 pin Hg / TR (1)

where

ρ = density (lb/ft3)

pin Hg = pressure (inches Hg)

TR = absolute temperature (Rankine)