Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!

Engineering ToolBox > Aluminum Channels

Dimensions and static parameters of Aluminum Channels

american standard steel channel

Dimensions and static properties of Aluminum Channels are indicated below.

Designation Dimensions Static Parameters
Moment of Inertia Section Modulus
Imperial
(in x in)
Depth
h
(in)
With
w
(in)
Web Thickness
s
(in)
Sectional Area
(in2)
Weight
(lb/ft)
Ix
(in4)
Iy
(in4)
Wx
(in3)
Wy
(in3)
2 x 1 2 1 0.13 0.49 0.58 0.288 0.05 0.29 0.06
2 x 1 1/4 2 1 1/4 0.17 0.91 1.07 0.546 0.14 0.55 0.18
3 x 1 1/2 3 1 1/2 0.13 0.97 1.14 1.41 0.22 0.94 0.22
3 x 1 3/4 3 1 3/4 0.17 1.36 1.60 1.97 0.42 1.31 0.37
4 x 2 4 2 0.15 1.48 1.74 3.91 0.60 1.95 0.45
4 x 2 1/4 4 2 1/4 0.19 1.98 2.33 5.21 1.0 2.60 0.69
5 x 2 1/4 5 2 1/4 0.15 1.88 2.21 7.88 1.0 3.15 0.64
5 x 2 3/4 5 2 3/4 0.19 2.63 3.09 11.1 2.1 4.45 1.14
6 x 2 1/2 6 2 1/2 0.17 2.41 2.83 14.4 1.5 4.78 0.90
6 x 3 1/4 6 3 1/4 0.21 3.43 4.03 21.0 3.8 7.0 1.8
7 x 2 3/4 7 2 3/4 0.17 2.73 3.21 22.1 2.1 6.3 1.1
7 x 3 1/2 7 3 1/2 0.21 4.01 4.72 33.8 5.1 9.7 2.2
8 x 3 8 3 0.19 3.53 4.15 37.4 3.3 9.4 1.6
8 x 3 3/4 8 3 3/4 0.25 4.92 5.78 52.7 7.1 13.2 2.8
9 x 3 1/4 9 3 1/4 0.23 4.24 4.98 54.4 4.4 12.1 1.9
9 x 4 9 4 0.29 5.93 6.97 78.3 9.6 17.4 3.5
10 x 3 1/2 10 3 1/2 0.25 5.22 6.14 83.2 6.3 16.6 2.6
10 x 4 1/4 10 4 1/4 0.31 7.11 8.36 116.2 13.0 23.2 4.5
12 x 4 12 4 0.29 7.04 8.27 159.8 11.0 26.6 3.9
12 x 5 12 5 0.35 10.1 11.8 239.7 25.7 40.0 7.6

Related Topics

Engineering Toolbox >

Related Documents

Google


Web The Engineering ToolBox
.