Bollards is common on quays in and are used when mooring ships and boats.

The effort force in a rope can be calculated
S = F e-μα (1)
where
S = effort force in the rope (N)
F = load (N)
e = 2.718..
μ = friction coefficient (aprox. 0.3 - 0.5 is common for a rope around a steel or cast iron bollard)
α = angle where the rope is in contact with the bollard (radians)
With a friction coefficient of 0.5 the effort force in the rope can be calculated as
S = F e-0.5 2π
= 0.043 F (N)
As we can see - one turn around the bollard reduces the required effort force to less than 5% of the load.
The retardation (negative acceleration) of a ship arriving at quay with velocity 0.05 m/s and stopped within 2 seconds, can be calculated as
a = dv/dt
= 0.05 (m/s) / 2 (s)
= 0.025 (m/s2)
With a mass of 20000 kg the required force F in the rope from the ship can be calculated as
F = m a
= 20000 (kg) 0.025 (m/s2)
= 500 N
The required effort force with a half turn around a bollard with a friction coefficient of 0.4 can be calculated as
S = F e-0.5 2π
= 500 (N) e-0.4 π
= 142 (N)