Resources, Tools and Basic Information for Engineering and Design of Technical Applications!
mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!
Engineering ToolBox > Pipe Threads for Tubes and Fittings where Pressuretight joints are made on the Threads - BS 21
Threads according BSi - British Standard Institute - BS 21 "Specification for pipe threads for tubes and fittings where pressure-tight joints are made on the threads" can be made as
BS parallel threads are also referred to as British Gas, British Pipe Parallel or Parallel Fastening Thread.
Common symbols used for the thread: BSP, BSPP, BSSPI, BSPF, BSPG, PS, Rp, G
The BSPP (parallel) male will mate with a BSPP (parallel) female or a female port.
Usually marked: G size ISO
BS taper threads are also referred to as British Standard Taper Pipe, Pipe Taper or Conical Thread.
Common symbols used for the thread: BSPT, BSPTr, PT, KR, R, Rc
Usually marked: Rc size ISO
Characteristics of BSPT taper threads:
| Pipe Size (inches) | Threads per Inch TPI - Pitch | Major Diameter OD (inches) |
| 1/16" | 28 | 0.304 |
| 1/8" | 28 | 0.383 |
| 1/4" | 19 | 0.518 |
| 3/8" | 19 | 0.656 |
| 1/2" | 14 | 0.825 |
| 5/8" | 14 | 0.902 |
| 3/4" | 14 | 1.041 |
| 7/8" | 14 | 1.189 |
| 1" | 11 | 1.309 |
| 1-1/4" | 11 | 1.650 |
| 1-1/2" | 11 | 1.882 |
| 1-3/4" | 11 | 2.116 |
| 2" | 11 | 2.347 |
| 2-1/4" | 11 | 2.587 |
| 2-1/2" | 11 | 2.960 |
| 3" | 11 | 3.460 |
Reference standards for BS 21 tapered pipe threads are: