Resources, Tools and Basic Information for Engineering and Design of Technical Applications!
mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!
Engineering ToolBox > Centrifugal Pumps and Viscosity
When a viscous fluid is handled by a centrifugal pump

The head, flow and capacity at other viscosities than used in the original documentation can be modifying with coefficients.
qv= cq q (1)
where
qv = flow compensated for viscosity (m3/h, gpm)
cq = viscosity flow coefficient
q = original flow according pump curve (m3/h, gpm)
hv= ch h (1)
where
hv = head compensated for viscosity (m, ft)
ch = viscosity head coefficient
h = original head according pump curve (m, ft)
μv= cμ μ (1)
where
μv = effciency compensated for viscosity
cμ = viscosity efficiency coefficient
μ = original efficiency according pump curve
Pv= qv hv ρv g / (3.6 106 μv) (1)
where
Pv = power compensated for viscosity (kW)
ρv = density of viscous fluid (kg/m3)
g = acceleration of gravity (9.81 m/s2)
Pv= qv hv SG / (3960 μv) (1)
where
Pv = power compensated for viscosity (bhp)
SG = specific gravity of viscous fluid