The storage volume for a compressed gas can be calculated using Boyle's Law:
pa Va = pc Vc (1)
where
pa = atmospheric pressure (14.7 psi, 101.325 kPa)
Va = volume of the gas at atmospheric pressure (cubic feet, cubic meter)
pc = compressed pressure (psi, kPa)
Vc = volume of the gas at compressed pressure (cubic feet, cubic meter)
The amount of free gas at atmospheric pressure in a given volume as a cylinder storage can be calculated my modifying (1) as:
Va = pc Vc / pa (1)
Gas can be stored in high-pressure cylinders ranging to 6000 psig (410 bar), normal-pressure cylinders ranging between 2000 and 2500 psig (140 and 175 bar) and low-pressure cylinders ranging up to 480 psig (34 bar).
The standard atmospheric air in a 250 cubic feet cylinder at 2000 psig (2014.7 psia) can be calculated as:
Va = 2,014.7 (psia) 250 (cubic feet) / 14.7 (psig)
= 34,264 (cubic feet)