Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!

Engineering ToolBox > Compressed Water Properties

Specific volume, enthalpy and entropy of compressed water

The table below can be used to determine specific volume (v), enthalpy (h), and entropy (s) of compressed water.

Saturation properties Temperature - t - (oC)
0.01 100 200 250 300 350 374.15
pressure
(bar)
ps 0.006112 1.01325 15.55 39.78 85.92 165.4 221.2
specific volume
(m3/kg)
vf 102 0.1000 0.1044 0.1157 0.1251 0.1404 0.1741 0.317
specific enthalpy
(kJ/kg)
hf 0 419 852 1086 1345 1671 2084
specific entropy
(kJ/kg K)
sf 0 1.307 2.331 2.793 3.255 3.779 4.430
Pressure
- p -
(bar)
Properties
1001) (v-vf) 102 -0.0005 -0.0006 -0.0009 -0.0011 -0.0007
(h-hf) +10 +7 +4 0 -2
(s-sf) 0.000 -0.008 -0.013 -0.014 -0.007
221.22) (v-vf) 102 -0.0011 -0.0012 -0.0020 -0.0029 -0.0051 -0.0107 0
(h-hf) +22 +17 +9 +1 -12 -34 0
(s-sf) +0.001 -0.017 -0.031 -0.040 -0.053 -0.071 0
500 (v-vf) 102 -0.0023 -0.0024 -0.0042 -0.0064 -0.0117 -0.0298 -0.161
(h-hf) +49 +38 +23 +8 -21 -94 -369
(s-sf) 0.000 -0.037 -0.068 -0.091 -0.134 -0.235 -0.670
1000 (v-vf) 102 -0.0044 -0.0044 -0.0075 -0.0111 -0.0191 -0.0427 -0.180
(h-hf) +96 +76 +51 +28 -17 -119 -415
(s-sf) -0.007 -0.070 -0.124 -0.164 -0.235 -0.385 -0.853

1) Saturation temperature (ts) 311.0oC

2) Saturation temperature (ts) 374.15oC

Related Topics

Engineering Toolbox >

Related Documents

Google


Web The Engineering ToolBox
.