Most signal systems - as sound power or sound intensity, human speech, sonar, microwaves, radio signals and fiber optics - can be described by
Transmitting power, path loss and receiver sensitivity are absolute power values - Watts in the SI system.
Decibel is a logarithmic unit used to describe the ratio of the signal level - power, sound pressure, voltage or intensity or several other things.
The decibel can be expressed as:
decibel = 10 log( P / Pref ) (1)
where
P = signal power (W)
Pref = reference power (W)
A decibel is one-tenth of a Bel, a seldom-used unit named for Alexander Graham Bell, inventor of the telephone.
Note! Doubling the signal level increases the decibel with 3 dB ( 10 log (2) ).
If we know the decibel value and the reference level, the absolute level can be calculated by transforming (1) to:
P = Pref 10(decibel / 10) (2)
The difference in sound intensity of 10-8 watts/m2 and 10-4 watts/m2 (10,000 units) can be calculated in decibels as
ΔLI = 10 log( (10-4 watts/m2) / (10-12 watts/m2) ) - 10 log( ( 10-8 watts/m2) / ( 10-12 watts/m2) )
= 40 dB
Increasing the sound intensity by a factor of