Engineering ToolBox > Vents

Vents of draining systems

Vents transports sewer gas through the building to the open air space. Properly installed the vents prevents siphoning traps and sewage gas leakage to the interior building.

Different codes in different jurisdictions exists and must be adhered to locally. In general we talk about

Individual vents

Individual vents serve individual fixtures.

individual sewage vent

This vents only one fixture but may connect into an other vent that extend to the open air.

Relief vents

Relief vents provide additional air to the drainage system where the primary vent is too far from the fixture.

relief sewage vent

 

Circuit vents

Circuit vents are used with more than one fixtures. A circuit vent is installed before the last fixture extend up to open air or connects to an other vent that extend to the outside

circuit sewage vent

Branch vents

Branch vents are vents extending horizontally that connects multiple vents together.

branch sewage vent

Stack vents

A vent stack is used only for the purpose of venting.

vent soil stack

Vents are normally sized by using the "Developed Length" (total linear footage of pipe making up the vent) method.