Appliance type Exhaust Temperature
(oF) (oC)
Chemical Oxidation 1350 - 1475 730 - 800
Annealing furnace 1,100 - 1,200 590 - 650
Fluidized-bed combustor 1,600 - 1,800 870 - 980
Natural-gas fired heating appliance with draft hood 360 182
Liquefied-petroleum gas-fired heating appliance with draft hood 360 182
Gas-fired heating appliance, no draft hood 460 238
Glass melting furnace 1,200 - 1,600 650 - 870
Oil-fired heating appliance, residential 560 293
Oil-fired heating appliance, forced draft over 400.000 Btu/h 360 182
Conventional incinerator 1,400 760
Controlled air incinerator 1,800 - 2,400 982 - 1,316
Pathological incinerator 1,800 - 2,800 982 - 1,538
Gas turbine exhaust 700 - 1,100 370 - 590
Diesel exhaust 1,000 - 1,200 540 - 650
Ceramic kilns 1,800 - 2,400 982 - 1,316