Mannings roughness coefficient values for some common materials

Manning's roughness coefficient values are used in the Manning's formula for flow calculation in open flow channels. Coefficients for some common used surface materials can be found in the table below:

Surface Material Manning's Roughness
Coefficient
- n -
Asbestos cement 0.011
Brass 0.011
Brick 0.015
Cast-iron, new 0.012
Concrete - Steel forms 0.011
Concrete - Wooden forms 0.015
Concrete - Centrifugally spun 0.013
Copper 0.011
Corrugated metal 0.022
Galvanized iron 0.016
Lead 0.011
Plastic 0.009
Steel - Coal-tar enamel 0.010
Steel - New unlined 0.011
Steel - Riveted 0.019
Wood stave 0.012