Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!

Engineering ToolBox > Methanol - Thermophysical Properties

Thermophysical properties methanol

Methanol (methyl alcohol, carbinol, wood alcohol, wood naptha or wood spirits) is a chemical compound with chemical formula CH3OH. Thermophysical properties for temperatures ranging -50-150 oC are indicated in the table below.

Temperature
(oC)
Latent Heat
(kJ/kg)
Liquid Density
(kg/m3)
Vapor Density
(kg/m3)
Liquid Thermal Conductivity
(W/moC)
Liquid Viscosity
(cP)
Vapor Viscosity
102 (cP)
Vapor Pressure
(bars)
Vapor Specific Heat
(kJ/kgoC)
Liquid Surface Tension
102 (N/m)
-50 1194 844 0.01 0.210 1.700 0.72 0.01 1.20 3.26
-30 1187 834 0.01 0.208 1.300 0.78 0.02 1.27 2.95
-10 1182 819 0.04 0.206 0.945 0.85 0.04 1.34 2.63
10 1175 801 0.12 0.204 0.701 0.91 0.10 1.40 2.36
30 1155 782 0.31 0.203 0.521 0.98 0.25 1.47 2.18
50 1125 764 0.77 0.202 0.399 1.04 0.55 1.54 2.01
70 1085 746 1.47 0.201 0.314 1.11 1.31 1.61 1.85
90 1035 724 3.01 0.199 0.259 1.19 2.69 1.79 1.66
110 980 704 5.64 0.197 0.211 1.26 4.98 1.92 1.46
130 920 685 9.81 0.195 0.166 1.31 7.86 1.92 1.25
150 850 653 15.9 0.193 0.138 1.38 8.94 1.92 1.04