Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!

Engineering ToolBox > Threads - Metric ISO 724

M Thread (metric ISO 724 thread) Standard in Europe

The M Thread - ISO 724:1993 "ISO general-purpose metric screw threads -- Basic dimensions" (DIN 13), the standard in Europe, is recognizable by its cylindrical outer and inner diameter and its precise outer diameter in millimeters.

There are three kinds of ISO metric threads:

The thread angle is 60o. The thread depth is 0.614 x pitch.

Designation

Metric threads are designated with a capital M plus an indication to their nominal outer diameter and their pitch:

M size x pitch

For instance:

M10 x 1.5

Metric Threads - Coarse Thread Pitches

Size - Nominal Diameter
(mm)
Pitch1)
(mm)
Clearance Drill
(mm)
Tap Drill
(mm)
M 1.60 0.35 1.8 1.25
M 2.00 0.40 2.4 1.60
M 2.50 0.45 2.90 2.00
M 3.00 0.50 3.40 2.50
M 3.50 0.60 3.90 2.90
M 4.00 0.70 4.50 3.30
M 5.00 0.80 5.50 4.20
M 6.00 1.00 6.60 5.00
M 8.00 1.25 9.00 6.80
M 10.00 1.50 12.00 8.50
M 12.00 1.75 14.00 10.20
M 14.00 2.00 16.00 12.00
M 16.00 2.00 18.00 14.00
M 20.00 2.50 22.00 17.50
M 22.00 2.50 25.00 19.50
M 24.00 3.00 27.00 21.00
M 27.00 3.00 30.00 24.00
M 30.00 3.50 33.00 26.50
M 36.00 4.00 40.00 32.00
M 42.00 4.50 46.00 37.50
M 48.00 5.00 53.00 43.00
M 56.00 5.50 62.00 50.50
M 64.00 6.00 70.00 58.00
M 68.00 6.00 74.00 62.00

1) For metric threads pitch is the distance between threads.

Metric Threads - Fine Thread Pitches

Size - Nominal Diameter
(mm)
Pitch1)
(mm)
Tap Drill
(mm)
M 1.0x0.2 0.20 0.80
M 1.1x0.2 0.20 0.90
M 1.2x0.2 0.20 1.00
M 1.4z0.2 0.20 1.20
M 1.6x0.2 0.20 1.40
M 1.8x0.2 0.20 1.60
M 2x0.25 0.25 1.75
M 2.2x0.25 0.25 1.95
M 2.5x0.35 0.35 2.10
M 3x0.35 0.35 2.60
M 3.5x0.35 0.35 3.10
M 4x0.5 0.50 3.50
M 4.5x0.5 0.50 4.00
M 5x0.5 0.50 4.50
M 5.5x0.5 0.50 5.00
M 6x0.75 0.75 5.20
M 7x0.75 0.75 6.20
M 8x0.75 0.75 7.20
M 8x1.0 1.00 7.00
M 9x0.75 0.75 8.20
M 9x 1 1.00 8.00
M 10x0.75 0.75 9.20
M 10x1 1.00 9.00
M 10x1.25 1.25 8.80
M 11x0.75 0.75 10.20
M 11x1 1.00 10.00
M 12x1 1.00 11.00
M 12x1.25 1.25 10.80
M 12x1.5 1.50 10.50
M 14x1.0 1.00 13.00
M 14x1.25 1.25 12.80
M 14x1.5 1.50 12.50
M 15x1 1.00 14.00
M 15x1.5 1.50 13.50
M 16x1 1.00 15.00
M 16x1.5 1.50 14.50
M 17x1.0 1.00 16.00
M 17x1.5 1.50 15.50
M 18x1.0 1.00 17.00
M 18x1.5 1.50 16.50
M 18x2.0 2.00 16.00
M 20x1.0 1.00 19.00
M 20x1.5 1.50 18.50
M 20x2.0 2.00 18.00
M 22x1.0 1.00 21.00
M 22x1.5 1.50 20.50
M 22x2.0 2.00 20.00
M 24x1.0 1.00 23.00
M 24x1.5 1.50 22.50
M 24x2.0 2.00 22.00
M 25x1.0 1.00 24.00
M 25x1.5 1.50 23.50
M 25x2.0 2.00 23.00
M 27x1.0 1.00 26.00
M 27x1.5 1.50 25.50
M 27x2.0 2.00 25.00
M 28x1.0 1.00 27.00
M 28x1.5 1.50 26.50
M 28x2.0 2.00 26.00
M 30x1.0 1.00 29.00
M 30x1.5 1.50 28.50
M 30x2.0 2.00 28.00
M 30x3.0 3.00 27.00
M 32x1.5 1.50 30.50
M 32x2.0 2.00 30.00
M 33x1.5 1.50 31.50
M 33x2.0 2.00 31.00
M 33x3.0 3.00 30.00
M 35x1.5 1.50 33.50
M 35x2.0 2.00 33.00
M 36x1.5 1.50 34.50
M 36x2.0 2.00 34.00
M 36x3.0 3.00 33.00
M 39x1.5 1.50 37.50
M 39x2.0 2.00 37.00
M 39x3.0 3.00 36.00
M 40x1.5 1.50 38.50
M 40x2.0 2.00 38.00
M 40x3.0 3.00 37.00
M 42x1.5 1.50 40.50
M 42x2.0 2.00 40.00
M 42x3.0 3.00 39.00
M 42x4.0 4.00 38.00
M 45x1.5 1.50 43.50
M 45x2.0 2.00 43.00
M 45x3.0 3.00 42.00
M 45x4.0 4.00 41.00
M 48x1.5 1.50 46.50
M 48x2.0 2.00 46.00
M 48x3.0 3.00 45.00
M 48x4.0 4.00 44.00
M 50x1.5 1.50 48.50
M 50x2.0 2.00 48.00
M 50x3.0 3.00 47.00
M 52x1.5 1.50 50.50
M 52x2.0 2.00 50.00
M 52x3.0 3.00 49.00
M 52x4.0 4.00 48.00
M 55x1.5 1.50 53.50
M 55x2.0 2.00 53.00
M 55x3.0 3.00 52.00
M 55x4.0 4.00 51.00
M 56x1.5 1.50 54.50
M 56x2.0 2.00 54.00
M 56x3.0 3.00 53.00
M 56x4.0 4.00 52.00
M 58x1.5 1.50 56.50
M 58x2.0 2.00 56.00
M 58x3.0 3.00 55.00
M 58x4.0 4.00 54.00
M 60x1.5 1.50 58.50
M 60x2.0 2.00 58.00
M 60x3.0 3.00 57.00
M 60x4.0 4.00 56.00
M 62x1.5 1.50 60.50
M 62x2.0 2.00 60.00
M 62x3.0 3.00 59.00
M 62x4.0 4.00 58.00
M 64x1.5 1.50 62.50
M 64x2.0 2.00 62.00
M 64x3.0 3.00 61.00
M 64x4.0 4.00 60.00
M 65x1.5 1.50 63.50
M 65x2.0 2.00 63.00
M 65x3.0 3.00 62.00
M 65x4.0 4.00 61.00
M 68x1.5 1.50 66.50
M 68x2.0 2.00 66.00
M 68x3.0 3.00 65.00
M 68x4.0 4.00 64.00
M 70x1.5 1.50 68.50
M 70x2.0 2.00 68.00
M 70x3.0 3.00 67.00
M 70x4.0 4.00 66.00
M 70x6.0 6.00 64.00
M 72x1.5 1.50 70.50
M 72x2.0 2.00 70.00
M 72x3.0 3.00 69.00
M 72x4.0 4.00 68.00
M 72x6.0 6.00 66.00
M 75x1.5 1.50 73.50
M 75x2.0 2.00 73.00
M 75x3.0 3.00 72.00
M 75x4.0 4.00 71.00
M 75x6.0 6.00 69.00
M 76x1.5 1.50 74.50
M 76x2.0 2.00 74.00
M 76x3.0 3.00 73.00
M 76x4.0 4.00 72.00
M 76x6.0 6.00 70.00
M 80x1.5 1.50 78.50
M 80x2.0 2.00 78.00
M 80x3.0 3.00 77.00
M 80x4.0 4.00 76.00
M 80x6.0 6.00 74.00
M 85x2.0 2.00 83.00
M 85x3.0 3.00 82.00
M 85x4.0 4.00 81.00
M 85x6.0 6.00 79.00
M 90x2.0 2.00 88.00
M 90x3.0 3.00 87.00
M 90x4.0 4.00 86.00
M 90x6.0 6.00 84.00
M 95x2.0 2.00 93.00
M 95x3.0 3.00 92.00
M 95x4.0 4.00 91.00
M 95x6.0 6.00 89.00
M 100x2.0 2.00 98.00
M 100x3.0 3.00 97.00
M 100x4.0 4.00 96.00
M 100x6.0 6.00 94.00

Related ISO Standards

Related Topics

Engineering Toolbox >

Related Documents

Google


Web The Engineering ToolBox
.