Engineering ToolBox > Potential Energy

Elevation and potential energy

When a body of mass is elevated against the gravitational force the potential energy can be expressed as

Ep = Fg dh

    =  m g dh (1)

where

Fg = gravitational force (weight) acting on the body (N)

Ep = potential energy (J)

m = mass of body (kg)

g = gravitational acceleration (9.81 m/s2)

dh = change in elevation (m)

Example - Potential Energy when body is elevated

A body of 1000 kg is elevated 10 m. The change in potential energy can be calculated as

 Ep = 1000 (kg) 9.81 (m/s2) 10 (m)

    = 98100 J

    = 98 kJ

    = 0.027 kWh