Resources, Tools and Basic Information for Engineering and Design of Technical Applications!
mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!
Pulley is a device that can increase the magnitude of the effort force.

With no pulley - the effort force is similar to the load - in opposite direction.
S = F (1)
where
S = effort force (N)
F = load (N)

With a single fixed pulley the effort force is similar (or more due to efficiency) to the load.
S = F (2)
The advantage with the single fixed pulley is that the direction of force is changed - it is possible to pull down instead of lifting up.

With a single moveable pulley the effort force is half (or more due to efficiency) of the load.
S = 1/2 F (3)

With a combined moveable pulley as above - the effort force is half (or more due to efficiency) of the load.
S = 1/2 F (4)

With two pulleys and the ropes as above - the effort force is 1/3 (or more due to efficiency) of the load.
S = 1/3 F (5)