Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!

Engineering ToolBox > Length of Relief Valve Vent Line

Equation for calculating length of safety valve vent line

The maximum length of a relief valve vent line

relief valve

can be calculated as

lm = 0.56 (1.1 pr + 14.7)2 di5 / qa2 (1)

where

lm = maximum length of vent line (feet)

pr = relief pressure (psi)

di = inside diameter (inches)

qa = air flow (lbs./min)

Related Topics

Engineering Toolbox >

Related Documents

Google


Web The Engineering ToolBox
.