Engineering ToolBox > Properties of Saturated Steam - Pressure in Bar
| Absolute pressure | Boiling point | Specific volume (steam) | Density (steam) | Specific enthalpy of liquid water (sensible heat) | Specific enthalpy of steam (total heat) | Latent heat of vaporization | Specific heat | |||
| (bar) | (oC) | (m3/kg) | (kg/m3) | (kJ/kg) | (kcal/kg) | (kJ/kg) | (kcal/kg) | (kJ/kg) | (kcal/kg) | (kJ/kg) |
| 0.02 | 17.51 | 67.006 | 0.015 | 73.45 | 17.54 | 2533.64 | 605.15 | 2460.19 | 587.61 | 1.8644 |
| 0.03 | 24.10 | 45.667 | 0.022 | 101.00 | 24.12 | 2545.64 | 608.02 | 2444.65 | 583.89 | 1.8694 |
| 0.04 | 28.98 | 34.802 | 0.029 | 121.41 | 29.00 | 2554.51 | 610.13 | 2433.10 | 581.14 | 1.8736 |
| 0.05 | 32.90 | 28.194 | 0.035 | 137.77 | 32.91 | 2561.59 | 611.83 | 2423.82 | 578.92 | 1.8774 |
| 0.06 | 36.18 | 23.741 | 0.042 | 151.50 | 36.19 | 2567.51 | 613.24 | 2416.01 | 577.05 | 1.8808 |
| 0.07 | 39.02 | 20.531 | 0.049 | 163.38 | 39.02 | 2572.62 | 614.46 | 2409.24 | 575.44 | 1.8840 |
| 0.08 | 41.53 | 18.105 | 0.055 | 173.87 | 41.53 | 2577.11 | 615.53 | 2403.25 | 574.01 | 1.8871 |
| 0.09 | 43.79 | 16.204 | 0.062 | 183.28 | 43.78 | 2581.14 | 616.49 | 2397.85 | 572.72 | 1.8899 |
| 0.1 | 45.83 | 14.675 | 0.068 | 191.84 | 45.82 | 2584.78 | 617.36 | 2392.94 | 571.54 | 1.8927 |
| 0.2 | 60.09 | 7.650 | 0.131 | 251.46 | 60.06 | 2609.86 | 623.35 | 2358.40 | 563.30 | 1.9156 |
| 0.3 | 69.13 | 5.229 | 0.191 | 289.31 | 69.10 | 2625.43 | 627.07 | 2336.13 | 557.97 | 1.9343 |
| 0.4 | 75.89 | 3.993 | 0.250 | 317.65 | 75.87 | 2636.88 | 629.81 | 2319.23 | 553.94 | 1.9506 |
| 0.5 | 81.35 | 3.240 | 0.309 | 340.57 | 81.34 | 2645.99 | 631.98 | 2305.42 | 550.64 | 1.9654 |
| 0.6 | 85.95 | 2.732 | 0.366 | 359.93 | 85.97 | 2653.57 | 633.79 | 2293.64 | 547.83 | 1.9790 |
| 0.7 | 89.96 | 2.365 | 0.423 | 376.77 | 89.99 | 2660.07 | 635.35 | 2283.30 | 545.36 | 1.9919 |
| 0.8 | 93.51 | 2.087 | 0.479 | 391.73 | 93.56 | 2665.77 | 636.71 | 2274.05 | 543.15 | 2.0040 |
| 0.9 | 96.71 | 1.869 | 0.535 | 405.21 | 96.78 | 2670.85 | 637.92 | 2265.65 | 541.14 | 2.0156 |
| 1 | 99.63 | 1.694 | 0.590 | 417.51 | 99.72 | 2675.43 | 639.02 | 2257.92 | 539.30 | 2.0267 |
| 1.1 | 102.32 | 1.549 | 0.645 | 428.84 | 102.43 | 2679.61 | 640.01 | 2250.76 | 537.59 | 2.0373 |
| 1.2 | 104.81 | 1.428 | 0.700 | 439.36 | 104.94 | 2683.44 | 640.93 | 2244.08 | 535.99 | 2.0476 |
| 1.3 | 107.13 | 1.325 | 0.755 | 449.19 | 107.29 | 2686.98 | 641.77 | 2237.79 | 534.49 | 2.0576 |
| 1.4 | 109.32 | 1.236 | 0.809 | 458.42 | 109.49 | 2690.28 | 642.56 | 2231.86 | 533.07 | 2.0673 |
| 1.5 | 111.37 | 1.159 | 0.863 | 467.13 | 111.57 | 2693.36 | 643.30 | 2226.23 | 531.73 | 2.0768 |
| 1.5 | 111.37 | 1.159 | 0.863 | 467.13 | 111.57 | 2693.36 | 643.30 | 2226.23 | 531.73 | 2.0768 |
| 1.6 | 113.32 | 1.091 | 0.916 | 475.38 | 113.54 | 2696.25 | 643.99 | 2220.87 | 530.45 | 2.0860 |
| 1.7 | 115.17 | 1.031 | 0.970 | 483.22 | 115.42 | 2698.97 | 644.64 | 2215.75 | 529.22 | 2.0950 |
| 1.8 | 116.93 | 0.977 | 1.023 | 490.70 | 117.20 | 2701.54 | 645.25 | 2210.84 | 528.05 | 2.1037 |
| 1.9 | 118.62 | 0.929 | 1.076 | 497.85 | 118.91 | 2703.98 | 645.83 | 2206.13 | 526.92 | 2.1124 |
| 2 | 120.23 | 0.885 | 1.129 | 504.71 | 120.55 | 2706.29 | 646.39 | 2201.59 | 525.84 | 2.1208 |
| 2.2 | 123.27 | 0.810 | 1.235 | 517.63 | 123.63 | 2710.60 | 647.42 | 2192.98 | 523.78 | 2.1372 |
| 2.4 | 126.09 | 0.746 | 1.340 | 529.64 | 126.50 | 2714.55 | 648.36 | 2184.91 | 521.86 | 2.1531 |
| 2.6 | 128.73 | 0.693 | 1.444 | 540.88 | 129.19 | 2718.17 | 649.22 | 2177.30 | 520.04 | 2.1685 |
| 2.8 | 131.20 | 0.646 | 1.548 | 551.45 | 131.71 | 2721.54 | 650.03 | 2170.08 | 518.32 | 2.1835 |
| 3 | 133.54 | 0.606 | 1.651 | 561.44 | 134.10 | 2724.66 | 650.77 | 2163.22 | 516.68 | 2.1981 |
| 3.5 | 138.87 | 0.524 | 1.908 | 584.28 | 139.55 | 2731.63 | 652.44 | 2147.35 | 512.89 | 2.2331 |
| 4 | 143.63 | 0.462 | 2.163 | 604.68 | 144.43 | 2737.63 | 653.87 | 2132.95 | 509.45 | 2.2664 |
| 4.5 | 147.92 | 0.414 | 2.417 | 623.17 | 148.84 | 2742.88 | 655.13 | 2119.71 | 506.29 | 2.2983 |
| 5 | 151.85 | 0.375 | 2.669 | 640.12 | 152.89 | 2747.54 | 656.24 | 2107.42 | 503.35 | 2.3289 |
| 5.5 | 155.47 | 0.342 | 2.920 | 655.81 | 156.64 | 2751.70 | 657.23 | 2095.90 | 500.60 | 2.3585 |
| 6 | 158.84 | 0.315 | 3.170 | 670.43 | 160.13 | 2755.46 | 658.13 | 2085.03 | 498.00 | 2.3873 |
| 6.5 | 161.99 | 0.292 | 3.419 | 684.14 | 163.40 | 2758.87 | 658.94 | 2074.73 | 495.54 | 2.4152 |
| 7 | 164.96 | 0.273 | 3.667 | 697.07 | 166.49 | 2761.98 | 659.69 | 2064.92 | 493.20 | 2.4424 |
| 7.5 | 167.76 | 0.255 | 3.915 | 709.30 | 169.41 | 2764.84 | 660.37 | 2055.53 | 490.96 | 2.4690 |
| 8 | 170.42 | 0.240 | 4.162 | 720.94 | 172.19 | 2767.46 | 661.00 | 2046.53 | 488.80 | 2.4951 |
| 8.5 | 172.94 | 0.227 | 4.409 | 732.03 | 174.84 | 2769.89 | 661.58 | 2037.86 | 486.73 | 2.5206 |
| 9 | 175.36 | 0.215 | 4.655 | 742.64 | 177.38 | 2772.13 | 662.11 | 2029.49 | 484.74 | 2.5456 |
| 9.5 | 177.67 | 0.204 | 4.901 | 752.82 | 179.81 | 2774.22 | 662.61 | 2021.40 | 482.80 | 2.5702 |
| 10 | 179.88 | 0.194 | 5.147 | 762.60 | 182.14 | 2776.16 | 663.07 | 2013.56 | 480.93 | 2.5944 |
| 11 | 184.06 | 0.177 | 5.638 | 781.11 | 186.57 | 2779.66 | 663.91 | 1998.55 | 477.35 | 2.6418 |
| 12 | 187.96 | 0.163 | 6.127 | 798.42 | 190.70 | 2782.73 | 664.64 | 1984.31 | 473.94 | 2.6878 |
| 13 | 191.60 | 0.151 | 6.617 | 814.68 | 194.58 | 2785.42 | 665.29 | 1970.73 | 470.70 | 2.7327 |
| 14 | 195.04 | 0.141 | 7.106 | 830.05 | 198.26 | 2787.79 | 665.85 | 1957.73 | 467.60 | 2.7767 |
| 15 | 198.28 | 0.132 | 7.596 | 844.64 | 201.74 | 2789.88 | 666.35 | 1945.24 | 464.61 | 2.8197 |
| 16 | 201.37 | 0.124 | 8.085 | 858.54 | 205.06 | 2791.73 | 666.79 | 1933.19 | 461.74 | 2.8620 |
| 17 | 204.30 | 0.117 | 8.575 | 871.82 | 208.23 | 2793.37 | 667.18 | 1921.55 | 458.95 | 2.9036 |
| 18 | 207.11 | 0.110 | 9.065 | 884.55 | 211.27 | 2794.81 | 667.53 | 1910.27 | 456.26 | 2.9445 |
| 19 | 209.79 | 0.105 | 9.556 | 896.78 | 214.19 | 2796.09 | 667.83 | 1899.31 | 453.64 | 2.9849 |
| 20 | 212.37 | 0.100 | 10.047 | 908.56 | 217.01 | 2797.21 | 668.10 | 1888.65 | 451.10 | 3.0248 |
| 21 | 214.85 | 0.095 | 10.539 | 919.93 | 219.72 | 2798.18 | 668.33 | 1878.25 | 448.61 | 3.0643 |
| 22 | 217.24 | 0.091 | 11.032 | 930.92 | 222.35 | 2799.03 | 668.54 | 1868.11 | 446.19 | 3.1034 |
| 23 | 219.55 | 0.087 | 11.525 | 941.57 | 224.89 | 2799.77 | 668.71 | 1858.20 | 443.82 | 3.1421 |
| 24 | 221.78 | 0.083 | 12.020 | 951.90 | 227.36 | 2800.39 | 668.86 | 1848.49 | 441.50 | 3.1805 |
| 25 | 223.94 | 0.080 | 12.515 | 961.93 | 229.75 | 2800.91 | 668.99 | 1838.98 | 439.23 | 3.2187 |
| 26 | 226.03 | 0.077 | 13.012 | 971.69 | 232.08 | 2801.35 | 669.09 | 1829.66 | 437.01 | 3.2567 |
| 27 | 228.06 | 0.074 | 13.509 | 981.19 | 234.35 | 2801.69 | 669.17 | 1820.50 | 434.82 | 3.2944 |
| 28 | 230.04 | 0.071 | 14.008 | 990.46 | 236.57 | 2801.96 | 669.24 | 1811.50 | 432.67 | 3.3320 |
| 29 | 231.96 | 0.069 | 14.508 | 999.50 | 238.73 | 2802.15 | 669.28 | 1802.65 | 430.56 | 3.3695 |
| 30 | 233.84 | 0.067 | 15.009 | 1008.33 | 240.84 | 2802.27 | 669.31 | 1793.94 | 428.48 | 3.4069 |
At atmospheric pressure (0 bar g, absolute 1 bar ), water boils at 100oC, and 417.51 kJ of energy are required to heat 1 kg of water from 0oC to its evaporating temperature of 100oC.
Therefore the specific enthalpy of water at 0 bar g (absolute 1 bar ) and 100oC is 417.51 kJ/kg, as shown in the table.
Another 2 257.92 kJ of energy are required to evaporate 1 kg of water at 100oC into 1 kg of steam at 100oC. Therefore at 0 bar g (absolute 1 bar) the specific enthalpy of evaporation is 2 257.19 kJ/kg, as shown in the table.
Total specific enthalpy for steam:
hs = 417.51 + 2 257.92
= 2 675.43 kJ/kg
Steam at atmospheric pressure is of a limited practical use because it cannot be conveyed under its own pressure along a steam pipe to the point of use.
At 7 bar g (absolute 8 bar), the saturation temperature of water is 170.42oC. More heat energy is required to raise its temperature to saturation point at 7 bar g than would be needed if the water were at atmospheric pressure. The table gives a value of 720.94 kJ to raise 1 kg of water from 0oC to its saturation temperature of 170oC.
The heat energy (enthalpy of evaporation) needed by the water at 7 bar g to change it into steam is actually less than the heat energy required at atmospheric pressure. This is because the specific enthalpy of evaporation decreases as the steam pressure increases. The evaporation heat is 2046.53 kJ/kg according the table.