Engineering ToolBox > Slurry Density

Calculate slurry density

Slurry is a mixture of solids and liquid. The density of a slurry can be calculated as

ρm = 100 / (cw / ρs  + (100 - cw) / ρl) (1)

where

ρm = density of slurry (lb/ft3, kg/m3)

c= concentration of solids by weight in the slurry (%)

ρs =  density of the solids (lb/ft3, kg/m3)

ρl =  density of liquid without solids (lb/ft3, kg/m3)

The slurry concentration by weight can be measured by evaporating a known weight of slurry and measuring the weight of dried solids.

Example - Calculating Slurry Density

The density of a slurry where

can be calculated as

 ρm = 100 / (30 / 2500  + (100 - 30) / 1000)

    = 1220 kg/m3

Slurry Density Calculator

The density of a slurry can be calculated with the calculator below.

solids concentration - (%)

density solid - (kg/m3, lb/ft3)

density liquid - (kg/m3, lb/ft3)

 