Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!

Engineering ToolBox > Water - Specific Heat Capacity at High Temperature

Specific heat capacity of water at higher temperatures - in Imperial units

When calculating mass and volume flow in water heating systems at high temperature, the specific heat capacity should be adjusted according the table below:

Temperature
- T -
(oF)
Specific Heat Capacity
- cp -
(Btu/lbm.oF)
200 1.005
210 1.007
212 1.008
220 1.010
230 1.012
240 1.013
250 1.015
270 1.020
280 1.022
290 1.025
300 1.032
310 1.035
320 1.040
330 1.042
340 1.047
350 1.052
370 1.062
380 1.070
390 1.077
400 1.085
420 1.097
430 1.107
440 1.115

Related Topics