Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!

Engineering ToolBox > Steam & Condensate Equations

Steam consumption and condensate generation formulas heating liquids or gas flows

Some common steam and condensate equations can be expressed as

Steam Heating

ms = h / 960 (1)

where

ms = steam mass flow rate (lbs./hr.)

h = heat flow rate (Btu/hr.)

Steam Heating Liquid Flow

ms = ql 500 SGl Cpl dtl / Ls (1)

where

ms = steam mass flow rate (lbs./hr.)

ql = volume flow liquid (gallons per minute, gpm)

SGl = specific heat capacity of the liquid (Btu/lb.oF)

Cpl = specific gravity of the fluid

dtl = temperature difference liquid (oF)

Ls = latent heat steam (Btu/lb)