Engineering ToolBox > Pressure Drop in Steam Pipes

Steam pipes and pressure drop diagrams - imperial and metric units

Pressure drop in steam pipes can be estimated with the diagrams below.

Imperial Units

steam pipe pressure drop diagram

The diagram is made for steam with pressure 100 psi. For other pressures use correction factors:

Pressure (psi) 0 5 10 30 60 90 100 110 150 200 250 300
Factor 6.9 5.2 4.3 2.4 1.5 1.1 1.0 0.92 0.70 0.55 0.45 0.38

Metric Units

steam pipe pressure drop diagram metric units

The diagram is made for steam with pressure  7 bar. For other pressures use correction factors:

Pressure (bar) 0 1 2 4 5 6 7 8.5 10 12 14 20
Factor 6.9 3.67 2.51 1.55 1.31 1.13 1.0 0.85 0.74 0.63 0.55 0.39