Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

Resources, Tools and Basic Information for Engineering and Design of Technical Applications!

mobile - visible on handheld devices - alternatively go to www.engineeringtoolbox.com!

Engineering ToolBox > Carbon and Stainless Steel Flanges - ASME/ANSI Class 2500

ASME/ANSI B16.5-1996 Pipe Flanges and Flanged Fittings - Class 2500 Flanges - outside and inside diameters, bolt circles, numbers and diameters of bolts

ASME/ANSI B16.5-1996 Pipe Flanges and Flanged Fittings - Class 2500 Flanges - outside and inside diameters, bolt circles, numbers and diameters of bolts for Weld neck, Threaded, Slip-on, Lap joint, Socket weld and Blind flanges.

Carbon and stainless steel qualities according ASME B16.5 Table 1A.

Pipe Size
(inches)
Outside Diameter
(inches)
Inside Diameter
(inches)
Number of Bolt Holes Bolt Hole Diameter
(inches) 1)
Bolt Circle
(inches)
1/2 5-1/4 - 4 7/8 3-1/2
3/4 5-1/2 - 4 7/8 3-3/4
1 6-1/4 - 4 1 4-1/4
1-1/4 7-1/4 - 4 1-1/8 5-1/8
1-1/2 8 - 4 1-1/4 5-3/4
2 9-1/4 - 8 1-1/8 6-3/4
2-1/2 10-1/2 - 8 1-1/4 7-3/4
3 12 - 8 1-3/8 9
4 14 - 8 1-5/8 10-3/4
5 16-1/2 - 8 1-7/8 12-3/4
6 19 - 8 2-1/8 14-1/2
8 21-3/4 - 12 2-1/8 17-1/4
10 26-1/2 - 12 2-5/8 21-1/4
12 30 - 12 2-7/8 24-3/8

1) Recommended bolts are 1/8 smaller than the nominal bolt hole diameters shown.

Related Topics

Engineering Toolbox >

Related Documents

Google


Web The Engineering ToolBox
.