Steel pipes - thermal expansion and expansion loop capacities

The expansion loop is a common way to absorb the temperature expansion in steel pipes. Expansion loops can be fabricated from standard pipes and elbows.

steel pipe expansion loop

Approximate Expansion Capacity (mm)
Nominal Pipe Size (mm) Width of Expansion Loop - w - (m)
0.5 1.0 1.5 2.0 2.5
25 35 130      
32 25 100 210    
40 20 70 150    
50   65 125 200  
65   50 100 150 220
80   40 75 125 190
100   35 65 115 150

steel pipe temperature expansion loop diagram

Related Topics

Engineering Toolbox >

Related Documents

Google


Web The Engineering ToolBox
.