Some common used thermal properties for water:

Thermal properties of water:

Temperature
- t -
(oC)
Absolute pressure
- p -
(kN/m2)
Density
- ρ -
(kg/m3)
Specific volume
- v -
(m3/kgx10-3)
Specific Heat
- cp -
(kJ/kgK)
Specific entropy
- e -
(kJ/kgK)
0 (Ice)   916.8      
0.01 0.6 999.8 100 4.210 0
4 (maximum density) 0.9 1000.0      
5 0.9 1000.0 100 4.204 0.075
10 1.2 999.8 100 4.193 0.150
15 1.7 999.2 100 4.186 0.223
20 2.3 998.3 100 4.183 0.296
25 3.2 997.1 100 4.181 0.367
30 4.3 995.7 100 4.179 0.438
35 5.6 994.1 101 4.178 0.505
40 7.7 992.3 101 4.179 0.581
45 9.6 990.2 101 4.181 0.637
50 12.5 988 101 4.182 0.707
55 15.7 986 101 4.183 0.767
60 20.0 983 102 4.185 0.832
65 25.0 980 102 4.188 0.893
70 31.3 978 102 4.191 0.966
75 38.6 975 103 4.194 1.016
80 47.5 972 103 4.198 1.076
85 57.8 968 103 4.203 1.134
90 70.0 965 104 4.208 1.192
95 84.5 962 104 4.213 1.250
100 101.33 958 104 4.219 1.307
105 121 954 105 4.226 1.382
110 143 951 105 4.233 1.418
115 169 947 106 4.240 1.473
120 199 943 106 4.248 1.527
125 228 939 106 4.26 1.565
130 270 935 107 4.27 1.635
135 313 931 107 4.28 1.687
140 361 926 108 4.29 1.739
145 416 922 108 4.30 1.790
150 477 918 109 4.32 1.842
155 543 912 110 4.34 1.892
160 618 907 110 4.35 1.942
165 701 902 111 4.36 1.992
170 792 897 111 4.38 2.041
175 890 893 112 4.39 2.090
180 1000 887 113 4.42 2.138
185 1120 882 113 4.45 2.187
190 1260 876 114 4.46 2.236
195 1400 870 115   2.282
200 1550 864 116 4.51 2.329
220 840 4.63
225 2550 834 120 4.65 2.569
240 814 4.78
250 3990 799 125 4.87 2.797
260 784 4.98
275 5950 756 132 5.20 3.022
300 8600 714 140 5.65 3.256
325 12130 654 153 6.86 3.501
350 16540 575 174 10.1 3.781
360 18680 528 190 14.6 3.921

Temperature
- t -
(oC)
Absolute pressure
- p -
(kN/m2)
Dynamic viscosity
- μ -
(Centipoise)
Kinematic
viscosity
- ν -
(m2/s)
x 10-6
Expansion
coefficient
( l / K )
x 10-3
Specific enthalpy
(kJ/kg)
Prandtl's no.
0.01 0.6 1.78 1.792 -0.07 0 13.67
5 0.9 1.52 0.160 21.0
10 1.2 1.31 1.304 0.088 41.9 9.47
15 1.7 1.14 0.151 62.9
20 2.3 1.00 1.004 0.207 83.8 7.01
25 3.2 0.890 0.257 104.8
30 4.3 0.798 0.801 0.303 125.7 5.43
35 5.6 0.719 0.345 146.7
40 7.7 0.653 0.658 0.385 167.6 4.34
45 9.6 0.596 0,420 188.6
50 12.5 0.547 0.553 0.457 209.6 3.56
55 15.7 0.504 0.486 230.5
60 20.0 0.467 0.474 0.523 251.5 2.99
65 25.0 0.434 0.544 272.4
70 31.3 0.404 0.413 0.585 293.4 2.56
75 38.6 0.378 0.596 314.3
80 47.5 0.355 0.365 0.643 335.3 2.23
85 57.8 0.334 0.644 356.2
90 70.0 0.314 0.326 0.665 377.2 1.96
95 84.5 0.297 0.687 398.1
100 101.33 0.281 0.295 0.752 419.1 1.75
105 121 0.267 440.2
110 143 0.253 461.3
115 169 0.241 482.5
120 199 0.230 0.249 0.860 503.7 1.45
125 228 0.221 524.3
130 270 0.212 546.3
135 313 0.204 567.7
140 361 0.196 0.215 0.975 588.7 1.25
145 416 0.190 610.0
150 477 0.185 631.8
155 543 0.180 653.8
160 618 0.174 0.189 1.098 674.5 1.09
165 701 0.169 697.3
170 792 0.163 718.1
175 890 0.158 739.8
180 1000 0.153 0.170 1.233 763.1 0.98
185 1120 0.149 785.3
190 1260 0.145 807.5
195 1400 0.141 829.9
200 1550 0.138 0.158 1.392 851.7 0.92
220 0.149 1.597 0.88
225 2550 0.121 966.8
240 0.142 1.862 0.87
250 3990 0.110 1087
260 0.137 2.21 0.87
275 5950 0.0972 1211
300 8600 0.0897 1345
325 12130 0.0790 1494
350 16540 0.0648 1672
360 18680 0.0582 1764