Engineering ToolBox > Wind Energy

Available wind energy

Available wind resources as a function of yearly average wind velocity and different typical terrains are indicated in the diagram below.

wind resources - yearly average wind velocity and terrain - diagram

The resources refer to the power present in the wind at level 50 m. Be aware that wind turbine efficiency is typical 20-30%.

Example - Available Wind Resources

The wind power resources at a sheltered location with average wind velocity 5 m/s is aprox. 140 W/m2 from the diagram above. The available energy output from a wind turbine with efficiency 25% and a operation time 8000 hour a year can be calculated like

140 W/m2 0.25 8000 (hr/year) = 280000 Wh/year = 280 kWh/year